MACHU test
Accelerated corrosion test for coatings as prescribed in the Qualicoat specifications.
Applicable on:
Coatings
Test method standards:
Qualicoat
Test procedure:
Test panels are immersed in a bath of water, sodium chloride and hydrogen peroxide. At the end of the test, the samples are checked for corrosion, blistering and detachment.
This method is often used as a screening tool or preliminary test for rapid evaluation (48 hour test) of corrosion resistance.
Lead time:
5 business days