MACHU test

 

Accelerated corrosion test for coatings as prescribed in the Qualicoat specifications.

Applicable on:

Coatings

Test method standards: 
Qualicoat

Test procedure:

Test panels are immersed in a bath of water, sodium chloride and hydrogen peroxide. At the end of the test, the samples are checked for corrosion, blistering and detachment.

This method is often used as a screening tool or preliminary test for rapid evaluation (48 hour test) of corrosion resistance.

Lead time:

5 business days

 

 